ETIC 1230 Manuel d'utilisateur Page 89

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 106
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 88
CONFIGURATION
Industrial router IPL-E User guide ref. 9015909-03 Page 89
19.3.2 Configuration
Select the “gateway” menu and then the “Transparent” menu and then
click “RAW UDP”.
Select the “Activate” option.
« Serial input buffer size” parameter (value 1 to 1024)
:
Sets the maximum size of an UDP frame.
“End of frame time-out” parameter (value 10 ms to 5 sec ) :
Sets the delay the gateway will wait before sending the UDP frame
towards the IP network when no characters are received from the serial
interface.
«UDP port number» parameter :
Sets the UDP port number.
If the Raw UDP gateway is assigned to both serial COM ports, the UDP
port numbers must be different on each port.
“IP addresses of the destination devices » table :
This table stores the IP addresses of the gateways to which the serial data,
encapsulated inside UDP, have to be sent.
A different UDP port number can be entered for each destination IP address.